Saturday 20 January 2018

Gas Safety Device (GSD) for LPG cylinder |Ws direct selling| direct selling package 3800/6500

 GSD:

 GAS SAFETY DEVICE is a device fixed at  the top of your LPG cylinder and a gas regulator is a fixed  at the top of this device. GSD prevents all major problems of  GAS LEAKAGE, GAS PIPE CUT OFF , GAS SUPPLY and many more problems.

HOW TO  READ GSD GAUGE DIAL

   

Green zone - If the needle of GSD dial is in this area adequate gas supply is indicated.

 Red zone - If the needle of GSD dial is in this area , low LPG level is indicated, further  to which refilling of cylinder would be required soon.

 



↑GAS SAFETY DEVICE↑

    FEATURES OF GSD   

 GSD will automatically shut-off the gas supply from the cylinder due to major leakages of gas caused due to : 

 a) The rupturing of a tube or pulling off the stove or regulator. 
b) The regulator failed due to function properly.
c) The tube catching fire.

In most of the cases  where hose rapture occurs and if there is insufficient flow due to blockage / restriction , or supply  line diameter ( internal diameter ), is too small GSD may not be activated .

Automatic shut off may occur if gas consumption is excessive at low cylinder pressure. However , if shut off continually occurs it is advisable to have the system safely checked immediately by an authorized gas fitter. Do not use the system until the problem has been rectified. In such situations it is also possible that cylinder nay need refilling.

Shut-off is indicated by GSD when dial needle suddenly returns to zero. If shut  off  occurs , the gas stove controls may be turned to OFF position and procedure for ' HOW TO TEST MINOR LEAKS ' should be repeated. If continuous shut-off occurs, the LPG system would need to be rectified by an Authorized Gas Fitter.

At extreme low temperature and severe winter conditions GSD will shut off gas supply and may not function properly.

INSTALLATION



  1. 3. 


    4.

HOW TO TEST FOR MINOR LEAKS: 

  1.  Keep the GSD knob in on condition and ensure that the burners of the gas stove are in off condition. The gauge dial needle will show pressure information.
  2. Turn-off the GSD knob and wait for few minutes, if needle of gauge dial drops slowly to zero level ,this indicates that there is leakage in the line between the pressure regulator and the gas stove.
  3. If the needle remains at the same position there is no leakage in the system.
  4. The above procedure can be repeated for more confirmation.
  1. ↑GSD BOX↑

    :CAUTIONS: 

    1. Carry out the minor leak testing each time the LPG is used, particularly when cylinder has been changed/ refilled or when connections have been tampered with. 

      2. If GSD continually shuts off the gas supply refer to section 'Features of GSD' as mentioned before.

      3. Never use GSD without the regulator supplied with your gas connection. Also do not mishandle , tamper with the GSD ( including gauge ) as this will void warranty and may result in malfunctioning there-by leading to accidents.

      4.Never use GSD without the regulator as this may bypass the shut off valve mechanism , thereby causing accidents.

      5. Never depress the GSD Gauge dial so much , that it allows the gas to flow out thereby - passing the shut off valve mechanism. This could cause an accident .Only depress the Gauge a few times , when the regulator is connected  to GSD  on one end and to the pipe connected to the gas stove at the other end.

       

       WATCH FULL VIDEO


      2


     

     





Gas Safety Device (GSD) for LPG cylinder |Ws direct selling| direct selling package 3800/6500

 GSD:   A  GAS SAFETY DEVICE is a device fixed at  the top of your LPG cylinder and a gas regulator is a fixed  at the top of this dev...